Test Results
Testing was conducted in
accordance with CAN4-S102-M88 "Standard Method of Test for Surface Burning
Characteristics of Building Materials and Assemblies" by Underwriters' Laboratories
of Canada. Following is a summary of the results of this test.
Material | 1FSR | 2SDC |
SPF Plywood, 12.7 mm nominal thickness, coated by Safecoat Exterior
with a single coat at a rate of 3.7 m2 per liter. |
15 | 15-30 |
1FSR - flame spread rating
2SDC - smoke developed
classification
NOTE: The flammability characteristics of different species of lumber vary. However, use of Spruce/Pine/Fir (SPF) which includes the most common building lumber provides an excellent basis for the comparison of various coatings.
HAZARD CLASS:
WHMIS B.3, D.26
TDG Class
3, UN1263, Packing group 2. See MSDS for detailed precautions.
PRECAUTIONS:
SAFECOAT Exterior is "WHMIS" regulated and is
subject to the "Transportation of Dangerous Goods Act and Regulations".
Identification and Certification Each container bears a label reading "Underwriters
Laboratories of Canada" or "Warnock Hersey Laboratories of Canada -
Listed - Fire Retardant Coating".
Guarantee/Warranty:
Recommendations for the use of our products are based on tests carried out at
government
approved labs. Manufacturer and seller are not responsible for
results where the product is
used under conditions beyond our control. Under
no circumstances will They
be liable for consequential
damages or damages to anyone in excess of
the purchase price of the product
or services.