SUPERTHERM ®
**TEST LISTINGS** |
||
1. ASTM |
( American Society for Testing and Materials ) |
|
![]() |
||
C 177 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus |
Passed |
|
C-236 (C236-89(1993)e1) - Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box - Testing for measuring R-values |
Passed | |
| C 411 Standard Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation | Passed | |
C 1371Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers and |
Passed | |
D 412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension |
Passed | |
| D 522 Standard Test Methods for Mandrel Bend Test of Attached Organic Coatings- resistance to cracking on metal or rubber type materials - 1"(25mm)bend - 1/4"(96mm)bend |
Passed | |
D 1653 Standard Test Methods for Water Vapor Transmission of Organic Coating Films |
Passed 3% | |
D 1654 Standard Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments Salt spray (fog/weathering) 450 Hour Salt Spray (Fog) |
Passed - 2000 hours | |
| D 3273-82T Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber D 3274 Standard Test Method for Evaluating Degree of Surface Disfigurement of Paint Films by Microbial (Fungal or Algal) Growth or Soil and Dirt Accumulation - Rating degree of fungal growth or soil and dirt accumulation on paint film |
Passed |
|
| Excellent (8 out of 9) | ||
D 3359 Standard Test Method for Measuring Adhesion by Tape Test |
Excellent | |
D 4060 Standard Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser |
Rated: 5B at 3000 cycles | |
D 6904 Standard Practice for Resistance to Wind-Driven Rain for Exterior Coatings Applied to Masonry |
Passed | |
D 7088 Standard Practice for Resistance to Hydrostatic Pressure for Coatings Used in Below Grade Applications Applied to Masonry |
Passed | |
E 84-89a Standard Test Method for Surface Burning Characteristics of Building Materials |
Passed | |
E 90 Standard test method for laboratory measurement of airborne sound transmission loss of building partitions |
Passed | |
E 96 Standard Test Methods for Water Vapor Transmission of Materials water vapor transmission |
Perm Rating - 8.8 avg | |
E 108 Standard Test Method for Fire Tests of Roof Coverings |
Passed | |
E 413 Standard Classification for Determination of Sound Transmission Class |
STC 40 | |
E 514 Standard Test Method for Water Penetration and Leakage Through Masonry Resistance to Wind Driven Rain |
Passed | |
E 903-96 Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres
|
Passed | |
| E 903-96 4 Year Retest | Passed | |
E 1269 Standard Test Method for Determining Specific Heat Capacity by Differential Scanning Calorimetry - TPRL |
Passed | |
| VTEC Laboratories review of TPRL report | ||
| Thermo physical Properties Research Laboratory | ||
E1737 Test Method for J-Integral Characterization of Fracture Toughness Flexibility |
Passed | |
G 53 exposure to UV, elevated temperature and humidity |
Passed | |
2. NASA |
(National Aeronautics and Space Administration) |
Passed |
![]() |
NHB 8060.1B/C Test 1 Flammability testing |
|
| - "K" no Toxic off gassing - "K" Rating for toxicity |
||
3. Factory Mutual Approval |
Passed | |
-Tested and Approved for Roofing and all other Applications |
Passed |
|
*Superior Products International II, Inc. is an active member of the NRCA. |
||
| 4. ICC | Approval (International Code Council) |
ICC Legacy Report #21-25 |
![]() |
Council that formally consolidates approvals for: |
|
| 5. ASHRAE 90.1 CODE COMPLIANCE | ||
| ( “U” value used to measure “area-weighted average”, insulated walls or roofs ) | ||
| 6. ECAP-CUL-1-03 - ENERGY CONSERVATION ASSISTANCE PROGRAM | ||
![]() |
||
- Standard Method for Comparing Utility Loads in Standard Constructed Buildings |
||
FLORIDA: |
||
DENVER: |
||
" This is the third time we have had the pleasure to test your product, it is rare that a single product will show such Repeatable Results in three totally different environments, South Florida and Denver Colorado and LaPerte Texas a true testimonial to your products ENERGY STAR rating." Alexander Othmer - Director FEO Energy Conservation Assistance / USF Tampa, Florida |
||
| 7. ENERGY STAR PROGRAM | Approved partner | |
![]() |
- Approved and accepted as an energy star partner for saving energy - ASTM E 903-96 Reflectivity=80% - Only 1% Reduction in Reflectivity over 3 Years (3% over 10 years) |
|
ASTM C 1371 and C 1549 Solar Reflectance and Thermal Emittance |
||
| 8. LEED - Leadership in Energy & Environmental Design | Approved product |
|
![]() |
- Qualifies under Sustainable Sites Credit 7.1 Heat Island Effect - non roof |
1 point |
- Qualifies under Sustainable Sites Credit 7.2 Heat Island Effect - roof |
1 point |
|
- Qualifies under Energy and Atmosphere Credit 1 Optimize Energy Performance ie. reduce thermal bridging |
1 - 10 points |
|
- Indoor Environmental Quality Credit 4.2 Low Emitting Materials - paint |
1 point | |
- Innovation & Design Process Credit 1.1 Innovation in Design |
1 - 5 points | |
May 1, 2007 (revised May 21, 2007) (Washington, DC) – The U.S. Green Building Council (USGBC) has announced that projects seeking certification under the LEED® Green Building Rating System™ can now earn an "Innovation in Design" point by using the Cradle to Cradle program for certified building products. |
||
- MBDC Cradle to Cradle GOLD CERTIFICATION |
||
| ASTM C 1371 and C 1549 Solar Reflectance and Thermal Emittance | ||
| 9. DNV Certification | ||
![]() |
- Passed DNV Audit and DNV Compliant and DNV Certification |
|
| 10. INTERNATIONAL MARITIME ORGANIZATION | ||
![]() |
IMO A. 653 (16) |
|
-Flame Spread Test for Bulkhead, Wall, and Ceiling Linings |
||
| 11. ABS | ||
| ABS Type Approval Program | Passed | |
| 12. Marine Safety Council | Passed | |
| MSC.41 (64) - Toxic Gas Generation - Used Colorimetric Gas Detector Tubes - Met All Toxic Gas Requirements |
||
| 13. CALIFORNIA COOL ROOF PROGRAM | Passed | |
| 14. State of California bureau of Home Furnishing and Thermal Insulation | License Number TE 1392 | |
| 15. CFIA | Passed | |
| 16. USDA | (United States Department of Agriculture) |
Passed |
![]() |
- Environmentally safe and safe for use around animals |
|
- Letter of Written Certification as Accepted by USDA from Manufacturer |
||
| 17. SOUND PROOFING Barrier | STC-Rated 48-51 |
|
- Sound Reduction: STC (Sound Transmission Coefficient) - Rated 48-51 as per ASTM E 90 |
||
| 18. Japanese Industrial Standards | Passed | |
- JIS A 5759 Reflectivity of sunlight on window or coating film |
||
- Reflective ratio 92.2 - Long Wave Radiation ratio 99.5 (Infrared) |
||
- 15 Year Re Test Solar Reflectance JIS R 3106 |
||
| 19 . China Center for Technical Testing of Non-Metallic Materials for Ship Building, China Ship-Building Corporation. | ||
National Bureau for the Inspection of Technologies (97) |
Passed - 2000 hours Salt, UV, Weathering. |
|
GB/T 1771-91 - Resistance to Salt Fog (2000 hours) |
Passed | |
GB/T 1866-88 - Manual Aging (2000 hours) |
Passed | |
GB/T 10834-88 - Resistance to Salt Water (1000 hours) |
Passed | |
GB/T 5219-85 - Adhesion (pulling apart method) |
4.07MPa |
|
GB/T 1733-93 - Boiling Water Immersion |
8 Hours |
|
| 20. Vodafone Testing Adana Report 2008 | ||
| 21. DEFICIENCIES INHERENT IN EXISTING CODES | ||