HPC® COATING test

December 23 2011

Some pictures of testing for a client.
1619 1620 1621
Before HPC® COATING the temperature of the pipes was 290°C
1623 1618
The coating was applied at a thickness of 7mm (276mils) - 10 mm ( 394 mils) DFT
1611 1615
The temperature was reduced to between. 56.4°C and 45.7°C.
1626 1624

Project Pictures courtesy of:
Fred Chu